<ArticleTitle>A Single-Phase Grid-tied PV based Trans-Z-Source Inverter Utilizing LCL filter and Grid Side Current Active Damping</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>67</FirstPage>
			<LastPage>77</LastPage>
			<ELocationID EIdType="pii">83609</ELocationID>
			
<ELocationID EIdType="doi">10.22109/jemt.2019.169380.1150</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Majid</FirstName>
					<LastName>Hosseinpour</LastName>
<Affiliation>Department of Electrical and Computer Engineering, University of Mohaghegh Ardabili, Ardabil, Iran</Affiliation>
<Identifier Source="ORCID">0000-0001-5074-4604</Identifier>

</Author>
<Author>
					<FirstName>Navid</FirstName>
					<LastName>Rasekh</LastName>
<Affiliation>Department of Electrical and Computer Engineering, University of Mohaghegh Ardabili, Ardabil, Iran</Affiliation>
<Identifier Source="ORCID">0000-0001-9672-4457</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2019</Year>
					<Month>01</Month>
					<Day>25</Day>
				</PubDate>
			</History>
		<Abstract>As grid-connected Photovoltaic (PV) based inverters are being used more, these systems play a more important role in the electricity generation by distributed power generators. Power injection to the grid needs to meet predefined standards. In this work, a PV based inverter consist of a Trans-Z-Source network performing as DC-DC power conversion level, is connected to the grid through a LCL filter. The connection through an LCL filter offers certain advantages, but it brings also the disadvantage of having a resonance frequency. A systematic mathematical design procedure for PR controller parameters along with active damping factor is presented and the overall control system leads to a considerably low value of grid current THD. Meanwhile the Maximum Power Point Tracking (MPPT) of the PV arrays is obtained by a modified INC method. Simulations in various conditions are carried out in MATLAB/Simulink environment and results depict suitable performance of the system with designed parameters.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Trans-Z-Source Inverter</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">PV systems</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">PR controller</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">LCL filter</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">active damping</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.jemat.org/article_83609_6fcb57361450a66f9aab87d86a03293f.pdf</ArchiveCopySource>